NEMA  >  Newsroom  >  News & Blog  >  The Power Index: Turning Industrial Efficiency Into American Energy Savings 

The Power Index: Turning Industrial Efficiency Into American Energy Savings 

By Zack Valdez, Ph.D., Senior Director, Regulatory & Industry Affairs, Industrial Core, NEMA

What is America’s next big energy savings opportunity is already within reach?

For a manufacturer investing in production, a building owner maintaining a property, or a water utility serving a community, money spent on unnecessary electricity is money unavailable for other priorities. Improving motor system efficiency in these environments can help lower operating costs and free funds for equipment, maintenance, and services. 

Electric motors convert electricity into motion that powers the pumps, fans, compressors, and other equipment that keep factories and buildings running. Together, the motor, the equipment it powers, and its controls form a motor system. The Lawrence Berkeley National Laboratory estimates that these systems in industrial and commercial facilities account for nearly 30% of U.S. electricity use and that right-sizing motors and adding variable frequency drives could save roughly 115 billion kilowatt-hours annually – equivalent to the annual electricity use of about 11 million American homes.  

Many of these systems face workloads that change throughout the day. Adjusting motor speed to match the work required can cut electricity bills using technology available today. Across factories and buildings nationwide, those savings can also help ease pressure on the grid.  

That matters as U.S. electricity demand is projected to grow more than 55% by 2050, according to a recent NEMA analysis. Meeting that growth requires both expanding our power supply and using electricity more efficiently. 

The Challenge: Measuring Potential Savings 

Variable-frequency drives, or VFDs, adjust motor speed to match the work required. But a facility owner considering an upgrade needs to answer practical questions: Which motor-and-drive combination should I choose? How much electricity could it save under my operating conditions? Will the savings justify the equipment, installation, and integration costs? 

NEMA’s Power Index (PI) Pilot Program, launched in September 2026 with support from member companies ABB, Danfoss, Innomotics, Nidec Motor Corporation, NORD Gear Corporation, Techtop Industries, Inc., and WEG, addresses one part of that decision: providing a consistent basis for comparing motor-and-drive energy performance. The goal of the PI Pilot Program is to create a consistent way to score and match motors and drives to help buyers evaluate options and give utilities a technical foundation for developing incentives. 

Making Performance Easier to Compare 

A motor’s efficiency at full load tells only part of the story. An office ventilation fan doesn’t need to run at full speed when the building is nearly empty. With appropriate controls, a drive attached to a motor can slow the fan to match ventilation needs, saving electricity. Evaluating the motor and drive together can reveal potential savings that a motor-only comparison can miss. 

Based on NEMA’s MG 10011 standard, the Power Index helps buyers compare energy performance under standardized load conditions relative to a fixed-speed motor baseline. For example, a Power Index of 45 indicates approximately 45% average energy savings under those rating conditions. Higher ratings indicate greater savings potential.

NEMA and the Northwest Energy Efficiency Alliance (NEEA) validated the Power Index approach by testing 19 motor-and-drive systems across three independent laboratories. Calculated ratings closely matched those derived by lab measurements. The findings support existing standardized test data to calculate Power Index ratings without separately testing rating conditions for every motor and drive combination. 

The Power Index provides a common reference for comparing potential energy savings under defined conditions. Translating that comparison into a facility’s expected savings and payback requires its actual load profile, operating hours, electricity tariff, and installed cost. 

For buyers, Power Index ratings offer a clearer starting point for investment decisions. For utilities, these ratings provide a consistent metric that could inform incentive eligibility and program design. 

A Better Match for Manufacturing 

Consider a manufacturer whose cooling water demand changes with production. A constant-speed pump may continue running at full speed while a valve restricts flow.  The facility uses a valve to limit flow rather than reducing pump speed to match demand. 

With a motor-and-drive system, the pump can slow as demand falls. Even a modest reduction in pump speed can produce significant electricity savings in the right application. 

With proper design and commissioning, the benefits can include more precise cooling control and lower electricity consumption while meeting production requirements. Reducing demand during a facility’s billing peak may also lower demand charges. The savings depend on how often the pump can slow and how the overall system operates. 

The Same Opportunity Beyond the Factory 

A university campus faces a similar challenge in its chilled-water system. Cooling needs change with weather, occupancy, and building schedules, yet constant-speed pumps may deliver more flow than necessary. 

VFDs, integrated with sensors and building controls, adjust pump speed to meet cooling needs and reduce operating costs while maintaining required temperatures. 

Comparable opportunities exist in commercial buildings, hospitals, and data centers. Well-designed motor-and-drive systems can cut electricity costs while keeping occupants comfortable and critical equipment running reliably. 

Turning a Proven Technology into Broader Adoption 

America needs more electrical infrastructure and practical ways to use existing systems more efficiently. 

By making motor-and-drive performance easier to compare, NEMA’s Power Index Pilot Program can help building owners, plant managers, and utilities make more informed decisions about energy-saving opportunities. 

Manufacturers can help expand the Power Index pilot by participating and providing performance data on motor-and-drive systems. Facility owners can identify applications where variable-speed systems could deliver meaningful savings, while utilities can explore using Power Index ratings to inform incentive programs. Together, these efforts help turn a proven technology into wider adoption, lower electricity bills, and a more productive use of America’s energy supply.

To learn more about the pilot or discuss participation, contact NEMA Sr. Director of Regulatory & Industry Affairs, Industrial Core, Zack Valdez, Ph.D.

NEMA's NEW Publication Store is live at www.makeitelectric.store. Visit and search our extensive catalog of 800+ standards and technical documents.